Revista de Chimie (Rev. Chim.), Year 2017, Volume 68, Issue 2, 396-400

https://doi.org/10.37358/RC.17.2.5462

Kamel Earar, Camelia Ana Grigore, Cristian Budacu, Lucia Carmen Trinca, Daniel Mareci, Cerasela Dorina Sincar

Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva

Abstract:

In the last decade, new titanium alloys such as Ti6Al7Nb and Ti6Al7NbN have been developed in different areas of dentistry. It is known that mechanical/electrochemical interactions accelerate corrosion in implant alloys, and these interactions can be reduced by improving the modular component machining tolerances or by improving the corrosion resistance. The aim of this study was to compare the Ti6Al7Nb and Ti6Al7NbN alloys corrosion resistance in AFNOR artificial saliva. Due to the nitrogen diffusion, the Ti6Al7NbN alloy presents more pronounced grain structure than Ti6Al7Nb. In the electrochemical estimations the polarisation data were converted into instantaneous corrosion rate values (jcorr). The obtained passivation properties were comparable for both alloys. The EIS spectra were best fitted using an equivalent circuit (EC) which was consistent with the model of a two-layer structure for the passive film. The electrochemical and corrosion behaviour of Ti6Al7NbN increased the occurrence of the implant alloy’s electrochemical degradation.
Keywords:
titanium based alloys; nitrogen; artificial saliva corrosion behaviour; EIS; SEM

Issue: 2017, Volume 68, Issue 2
Pages: 396-400
Publication date: 2017/3/15
https://doi.org/10.37358/RC.17.2.5462
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
EARAR, K., GRIGORE, C.A., BUDACU, C., TRINCA, L.C., MARECI, D., SINCAR, C.D., Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva, Rev. Chim., 68(2), 2017, 396-400.

Vancouver
Earar K, Grigore CA, Budacu C, Trinca LC, Mareci D, Sincar CD. Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva. Rev. Chim.[internet]. 2017 Feb;68(2):396-400. Available from: https://doi.org/10.37358/RC.17.2.5462


APA 6th edition
Earar, K., Grigore, C.A., Budacu, C., Trinca, L.C., Mareci, D. & Sincar, C.D. (2017). Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva. Revista de Chimie, 68(2), 396-400. https://doi.org/10.37358/RC.17.2.5462


Harvard
Earar, K., Grigore, C.A., Budacu, C., Trinca, L.C., Mareci, D., Sincar, C.D. (2017). 'Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva', Revista de Chimie, 68(2), pp. 396-400. https://doi.org/10.37358/RC.17.2.5462


IEEE
K. Earar, C.A. Grigore, C. Budacu, L.C. Trinca, D. Mareci, C.D. Sincar, "Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva". Revista de Chimie, vol. 68, no. 2, pp. 396-400, 2017. [online]. https://doi.org/10.37358/RC.17.2.5462


Text
Kamel Earar, Camelia Ana Grigore, Cristian Budacu, Lucia Carmen Trinca, Daniel Mareci, Cerasela Dorina Sincar,
Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva,
Revista de Chimie,
Volume 68, Issue 2,
2017,
Pages 396-400,
ISSN 2668-8212,
https://doi.org/10.37358/RC.17.2.5462.
(https://revistadechimie.ro/Articles.asp?ID=5462)
Keywords: titanium based alloys; nitrogen; artificial saliva corrosion behaviour; EIS; SEM


RIS
TY - JOUR
T1 - Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva
A1 - Earar, Kamel
A2 - Grigore, Camelia Ana
A3 - Budacu, Cristian
A4 - Trinca, Lucia Carmen
A5 - Mareci, Daniel
A6 - Sincar, Cerasela Dorina
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2017
VL - 68
IS - 2
SP - 396
EP - 400
UR - https://doi.org/10.37358/RC.17.2.5462
KW - titanium based alloys
KW - nitrogen
KW - artificial saliva corrosion behaviour
KW - EIS
KW - SEM
ER -


BibTex
@article{RevCh2017P396,
author = {Earar Kamel and Grigore Camelia Ana and Budacu Cristian and Trinca Lucia Carmen and Mareci Daniel and Sincar Cerasela Dorina},
title = {Electrochemical Behaviour of Titanium Based Biomaterials in Artificial Saliva},
journal = {Revista de Chimie},
volume = {68},
number = {2},
pages = {396-400},
year = {2017},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.17.2.5462},
url = {https://revistadechimie.ro/Articles.asp?ID=5462}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice